Products
2-Hydroxyethyl Methacrylate
- Product Name: 2-Hydroxyethyl Methacrylate
- Chemical Name (IUPAC): 2-hydroxyethyl 2-methylprop-2-enoate
- CAS No.: 868-77-9
- Chemical Formula: C6H10O3
- Form/Physical State: Liquid
- Factroy Site: No.30 Fuduihe Road, Xuwei New District, Lianyungang, Jiangsu, China
- Price Inquiry: sales7@ascent-chem.com
- Manufacturer: Lianyungang Petrochemical Co., Ltd
- CONTACT NOW
- 2-Hydroxyethyl Methacrylate is a methacrylate monomer in liquid form, commonly used in polymer and coatings industries, where high reactivity and hydrophilicity are required.
| HS Code | 784115 |
| Cas Number | 868-77-9 |
| Chemical Formula | C6H10O3 |
| Molar Mass | 130.14 g/mol |
| Appearance | Colorless liquid |
| Odor | Mild, characteristic odor |
| Density | 1.073 g/cm3 at 20°C |
| Boiling Point | 213°C |
| Melting Point | -12°C |
| Solubility In Water | Miscible |
| Flash Point | 98°C (closed cup) |
| Viscosity | 6 mPa·s at 20°C |
As an accredited 2-Hydroxyethyl Methacrylate factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 2-Hydroxyethyl Methacrylate, 1 liter, packaged in a sealed amber glass bottle with a tamper-evident cap and hazard labeling. |
| Container Loading (20′ FCL) | 20' FCL: Typically loads 16 metric tons of 2-Hydroxyethyl Methacrylate, packed in 200 kg drums or 1,000 kg IBC totes. |
| Shipping | 2-Hydroxyethyl Methacrylate is typically shipped in tightly sealed containers, such as drums or bottles, to prevent contamination and polymerization. The chemical should be kept away from heat, light, and incompatible substances, and transported under cool, dry conditions. Proper hazard labeling and documentation in accordance with regulations are required for safe shipping. |
| Storage | 2-Hydroxyethyl Methacrylate (HEMA) should be stored in a cool, dry, well-ventilated area, away from heat, direct sunlight, and sources of ignition. Keep the container tightly closed and away from oxidizing agents, reducing agents, and strong acids or bases. Store in a corrosion-resistant container with a suitable liner. Avoid freezing and protect from light to prevent polymerization. |
| Shelf Life | 2-Hydroxyethyl Methacrylate typically has a shelf life of 12 months when stored unopened, away from heat, light, and moisture. |
Applications of 2-Hydroxyethyl Methacrylate in Industrial Manufacturing
As a direct manufacturer of 2-Hydroxyethyl Methacrylate, we support established supply chains in multiple industrial segments, providing a consistent monomer for formulating advanced polymers, hydrogels, and coatings. Our technical guidance extends from raw material integration to process optimization for downstream application environments.
1. Hydrophilic Contact Lens Polymers
Ophthalmic device manufacturers consistently select this raw material as the main comonomer in the production of soft contact lens hydrogels. Regulatory bodies require strict safety and monomer purity specifications, especially concerning unreacted residuals and extractables that may contact the eye. Integrators introduce the material during the lens-molding polymerization stage; its presence determines mechanical properties, oxygen permeability, and moisture retention in the final product.
Industry compliance standards
- ISO 18369-3 (Ophthalmic optics - Contact lenses - Part 3: Measurement methods for physical properties)
- US FDA 21 CFR 820 (Quality System Regulation for medical devices)
- EN ISO 10993-1 (Biological evaluation of medical devices)
- USP Chapter <660> (Glass Containers), when utilized in container-closure systems
Typical usage ratio
- 38% to 70% by weight of the monomer mix in soft contact lens formulations. Final proportion depends on targeted water content and mechanical performance.
Downstream process integration
- Direct addition to lens precursor formulation, followed by UV or thermal curing in lens molds. Post-polymerization extraction protocols remove unreacted residues.
Final product types
- Daily-wear soft contact lenses
- Extended-wear silicone hydrogel lenses
- Colored and decorative lens products for medical or cosmetic use
2. Dental Restorative Composites
In dental laboratories and chairside systems, this monomer acts as a component in light-curable resin matrices for restorative, adhesive, and impression materials. It enables fine tuning of viscosity and crosslink density, contributing to superior wetting of filler particles and controlled curing shrinkage. The monomer enters the formulation and is cured with photoinitiator systems during in-situ polymerization, subject to dental device standards.
Industry compliance standards
- ISO 4049 (Dentistry - Polymer-based restorative materials)
- ISO 10993 series (Biological evaluation of dental materials)
- US FDA 21 CFR Part 872 (Dental devices)
- ADA Specification No. 27 (Direct Filling Resins)
Typical usage ratio
- 10% to 25% by weight in resin blend, depending on required flow and curing characteristics.
Downstream process integration
- Mixed with dimethacrylates and inorganic fillers; photopolymerized with visible-light initiator under blue light in clinical or laboratory settings. Integrated in both bulk-fill and flowable resin composites.
Final product types
- Direct and indirect dental restorative resins
- Dental adhesives and sealants
- Impression material matrices
- Temporary crown and bridge systems
3. UV-Curable Industrial Coatings
Coating formulators target this monomer as a hydrophilic crosslinker in UV-cure acrylate systems for specialty applications on plastics, glass, and metal. Its controlled hydrophilicity improves adhesion to polar substrates and enables greater scratch resistance or anti-fogging effects in transparent and semi-transparent finishes. Introduced at the pre-polymer mixing stage, it forms part of the reactive diluent component in 100% solids UV-curing lines.
Industry compliance standards
- ISO 12944 (Paints and varnishes – Corrosion protection of steel structures by protective paint systems)
- REACH Annex XVII (Restriction of certain hazardous substances)
- RoHS 2011/65/EU (Restriction of Hazardous Substances in coatings for electronics)
- GB 18582-2020 (Limits of harmful substances in interior architectural coatings, PRC)
Typical usage ratio
- 5% to 20% by weight of total monomer composition, with adjustments based on substrate adhesion and required film flexibility.
Downstream process integration
- Blended with urethane acrylate oligomers, photoinitiators, and additives; applied by roll-coating, spray, or curtain coating equipment; cured by in-line UV lamp exposure on industrial finishing lines.
Final product types
- Scratch-resistant coatings for automotive displays
- Anti-fog coatings for optical lenses and face shields
- Protective varnishes for electronic panel substrates
- UV-curable inks for plastic packaging
4. Ion-Exchange Resin Manufacturing
This advanced monomer supports functionalization of acrylate-based backbones in the synthesis of anion and cation exchange resins. Reactive sites formed during polymer bead manufacturing enable precise control of pore size, swelling, and ionic capacity. Producers incorporate this raw material at the aqueous suspension polymerization stage, producing highly crosslinked resins for separation and purification industries that must comply with stringent safety and extractable standards.
Industry compliance standards
- US FDA 21 CFR 173.25 (Ion-exchange resins for food processing)
- ACS Reagent Chemicals (Quality requirements for resin raw materials)
- EU Regulation (EC) No 1935/2004 (Materials and articles intended to come into contact with food)
- NSF/ANSI 44 (Residential cation exchange water softeners)
Typical usage ratio
- 3% to 12% by weight in the bead matrix, depending on desired crosslink density and swelling profile.
Downstream process integration
- Suspension-polymerized with styrene and divinylbenzene or similar monomers; functional groups introduced by post-polymerization modification or grafting for tailored selectivity in resins.
Final product types
- Anion-exchange resins for water purification
- Cation-exchange resins for softening or demineralization
- Chromatography resin beads for bioprocessing
- Resins for pharmaceutical and food processing filtration
5. Adhesive and Sealant Formulations for Electronics
Electronics and optoelectronics assemblers use this monomer in the formulation of UV- and dual-cure adhesives designed to bind glass, plastics, and circuit substrates. Its hygroscopicity, controlled flexibility, and polar nature contribute to strong, non-corrosive bonds at fine interfaces. The monomer enters at the blending stage of high-purity formulations, which must conform to performance requirements and substance restrictions for electronics.
Industry compliance standards
- IPC-4101D (Base materials for printed boards)
- RoHS 2011/65/EU (Electrical/Electronic safety)
- UL 94 (Flammability ratings in resins and adhesives)
- JIS C5010 (Specifications for adhesives in electrical/electronic applications, Japan)
Typical usage ratio
- 7% to 18% by weight in adhesive base, modulated for balance of bond strength, clarity, and flexible modulus.
Downstream process integration
- Combined with monomers and oligomers in the adhesive formulation tank; degassed and dispensed via automated nozzles; cured by UV LEDs or hybrid heat/UV systems on assembly lines.
Final product types
- Optical bonding adhesives for display panels
- Chip encapsulants and sealants in microelectronics
- Structural adhesives for camera module assemblies
- Moisture-resistant glues for flexible printed circuits
6. Medical Hydrogel Patches and Drug Delivery Devices
Pharmaceutical manufacturers employ this monomer to prepare highly absorbent hydrogel matrices in medical dressings and transdermal drug delivery systems. The hydrophilic nature enhances water uptake and controllable drug release profiles, with production lines adhering to pharmaceutical-grade manufacturing controls. The compound integrates at the hydrogel synthesis stage and must comply with global device and excipient specifications.
Industry compliance standards
- Ph. Eur. monograph 0343 (Hydroxyethyl methacrylate copolymer, excipient quality)
- US FDA 21 CFR Part 4 (Combination product GMPs)
- GB/T 16886.1-2011 (Biological evaluation of medical devices, China)
- ISO 13485 (Medical device quality management systems)
Typical usage ratio
- From 20% to 50% by weight in matrix blends, adjusted for drug loading capacity and patch flexibility requirements.
Downstream process integration
- Combined with crosslinkers and functional excipients in hydrogel precursor solution; cast into patch films or molded reservoirs; cured by controlled thermal/UV process; pads laminated to medical-grade backing films.
Final product types
- Transdermal drug delivery patches
- Hydrogel wound dressings for wound care management
- Controlled release implantable devices
- Absorbent gel sheets for scar therapy and burn treatment
Competitive 2-Hydroxyethyl Methacrylate prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615371019725 or mail to sales7@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8615371019725
Email: sales7@ascent-chem.com
Get Free Quote of Lianyungang Petrochemical Co., Ltd
Flexible payment, competitive price, premium service - Inquire now!
- 2-Hydroxyethyl Methacrylate is manufactured under an ISO 9001 quality system and complies with relevant regulatory requirements.
- COA, SDS/MSDS, and related certificates are available upon request. For certificate requests or inquiries, contact: sales7@ascent-chem.com.
Understanding 2-Hydroxyethyl Methacrylate: Real Insights from Our Production Floor
The Basics and Our Model
In the chemical industry, experience with 2-Hydroxyethyl Methacrylate, usually called HEMA, comes from the daily routine inside reactor halls. Every day, production specialists see firsthand how critical chemical purity and handling practices affect the end-use outcomes of this monomer. The most widely requested grade runs at purity levels above 99%, where impurities like Ethylene Glycol and Methacrylic Acid stay below tight limits. With HEMA, subtle differences in trace organics or water content quickly show up when customers move on to polymerization. Our model consistently produces material with a minimum purity above 99.5%. Every batch undergoes gas chromatography and moisture analysis before filling drums or bulk tanks, since even a small difference in water content can lead to changes during polymer forming.
The Experience with Polymerization
HEMA's popularity grows from its performance as a reactive monomer. In the acrylics field, its dual functionality—courtesy of both methacrylate and hydroxyethyl groups—lets formulators achieve things you won’t get with standard methyl methacrylate or other basic building blocks. It adds flexibility and adhesion to copolymer networks and helps enhance hydrophilicity in materials destined for healthcare uses.
Years ago, we followed the shift toward hydrogels for contact lens materials. Back then, polymer scientists looked at swelling behavior and oxygen permeability; both depend heavily on HEMA’s molecular structure and purity. With better controls over trace contaminants, our reactors turn out HEMA that customers report to be more predictable for consistent crosslinking density and water uptake. These two properties turned HEMA into the main backbone for soft lens manufacturing, and we’ve seen similar needs from medical device makers, printing ink formulators, and dental material producers—every sector brings its own quirks, but they all rely on the reproducibility of the monomer.
Differences from Other Methacrylate Monomers
The first thing anyone in production notices is the difference between HEMA and its cousins, like Methyl Methacrylate (MMA), Butyl Methacrylate (BMA), or Ethyl Methacrylate (EMA). MMA, for example, lacks the hydroxyethyl group—this one functional group, with its hydrophilic properties, changes everything. While MMA makes brittle, glass-like plastics, HEMA-based polymers feel softer and pick up water readily. In one set of tests we ran, a copolymer with 50% HEMA could swell up to 38% by mass in water, which would never happen with a similar MMA-based material.
Our plant allows us to produce HEMA on lines previously used for BMA and MMA. Switching over always means extra cleaning—residues in the circuit interact differently with HEMA, sometimes catalyzing premature polymerization. By fine-tuning initiator concentrations, we prevent runaway reactions, and this gives us reliability that specialty formulators, particularly in the adhesives and coatings sectors, regularly cite as a big advantage over low-spec HEMA from distributors.
Day-to-Day Realities in Handling and Storage
HEMA cups its own handling quirks, mostly due to its higher viscosity and reactivity. Storage can’t just mimic MMA or similar monomers. At our sites, every tank gets nitrogen blanketing since oxygen exposure sets off gradual polymerization over months. Technicians use cooling jackets to keep storage temperatures under 25°C. Even during drum filling, we monitor temperature and inhibitor levels—up-to-date tracking prevents quality drift. Our operators have seen drums left in poorly ventilated sheds, then returned months later, already gelling. Continuous operator training and close communication with bulk users reduced batch returns. Even now, direct feedback from polymer labs shapes our inhibitor dosing and storage recommendations.
Application Feedback: From Biomedical to Inks
HEMA sits right at the intersection between performance and versatility. In our experience, the dental field remains one of the most demanding: HEMA-based adhesives must spread quickly and cure without voids. We’ve fielded calls from dental resin manufacturers looking for advice on viscosity profiles that match automatic dispensing machines. Only practical plant experience reveals how autoclave cleaning or subtle differences in inhibitor addition change these rheological properties. One dental customer credits their decreased error rate to direct collaborative studies with our technical team on possible peroxide breakdown.
Within medical polymers, batch traceability comes up in every on-site audit. Our systems keep batch consignment data online for years, with each lot referenced back through GC-MS logs. This transparency satisfies even the most stringent third-party auditors and allows us to tweak production methods without losing product consistency—one of the biggest headaches for regulatory-focused users.
Offset printing and textile inks provide another set of production challenges. Our HEMA grade responds well in radiation-curable formulations, and our team helps troubleshoot the odd cloudiness or yellowing that shows up in test runs. These issues usually tie back to moisture uptake during transfer or residual inhibitors if batches sit idle for longer than planned. To address these, we keep additional QC capacity for final packaging checks and run customer-specific retention samples just in case their ink sacks roll off a press and need investigation months later.
Environmental and Safety Experience on the Ground
Few people outside the industry guess how much time goes toward safety and environmental management. At our factory, production never moves forward without inhibitor checks; the risk of runaway exothermic reaction remains top of mind. Even a 2-liter spill left unseen in a drainage ditch during summer heat can cure into a solid plug, risking plant downtime for days while maintenance crews clean out the system. All HEMA drums ship with a clear record of last inhibitor addition, and every shipment to large users comes with handling guidance refined by years of emergency response experience.
Local regulatory changes forced us to increase secondary containment and invest in vapor monitoring. Even so, open collaboration with transit partners and storage site staff taught us more than any consultant could. For example, a logistics coordinator once flagged leaks in the vapor return line—investigating this led to a switch in valve suppliers, lowering HEMA vapor losses by nearly 40% over subsequent quarters. These ground-level improvements don’t show up on spec sheets but keep our own crews, and those further down the supply chain, out of trouble.
Dealing with Customer-Specific Challenges
It’s not rare to get calls from R&D teams running small pilot reactors. Sometimes, their results deviate from published methods. From these conversations, we’ve learned that water content and how HEMA gets metered into their system often matter more than the branded initiator they’re using. Overdosing the initiator or trying to cut cycle times leads to lower copolymer molecular weights and unanticipated sticky residues. Sharing our in-house knowledge on feed rates, mixing order, and headspace control often fixes their process in just a day.
Some international users run closed reactors with robot arms, thinking that means the process stays under control. More than once, we’ve discovered that solvent extraction steps built for local HEMA suppliers don’t line up with the material we ship. HEMA from our line features lower trace aldehyde and improved color thanks to extra polishing passes. This means customers get fewer off-smells during their own processing, but only if they adjust their formulations accordingly. Our experience solving these mismatches, often during late-night video calls, builds lasting customer loyalty.
Why Raw Material Consistency Matters
For continuous polymer production, maintaining identical batch quality matters more than the stated purity alone. Our chemists test for residual inhibitors before and after filling, checking for Hydroquinone levels below the threshold that could stall a UV cure or create uneven crosslinking zones in a polymer block. This same inhibitor profile shows up in every audit. Large contact lens manufacturers or dental materials plants pull dozens of sample vials from each batch, and even a 0.1% difference in molecular weight distribution prompts a full investigation. Through years of collaboration with some of the most demanding clients, our process has adapted to deliver not just chemical numbers but real-world predictability.
Mistakes in consistency often mean whole production runs turn out defective. We once traced a series of slow cure rates in a customer’s photopolymer line to a minor formulation change in our stabilizer system. Because we keep decades of batch data and sample archives, isolating the root cause happens fast. Our lab team holds monthly review sessions to adjust output to current customer feedback and raw material fluctuations. This direct channel between users and production avoids the classic cycle of blame and rework common with less involved suppliers.
Packaging and Transit: Practical Issues That Matter
Shipping HEMA looks simple on paper, but real-world incidents shaped our selection of drum linings, bungs, and seal types. Epoxy linings protect HEMA from trace metals that would otherwise introduce color or initiate unwanted polymerization. A few years back, an importer flagged cloudiness in a full container load. Sampling revealed that metal fittings used at a transfer point had corroded; we retailored our export line with PTFE gaskets and dedicated stainless steel couplings.
Long ocean journeys also come with their own challenges. Barometric shifts and temperature swings degrade inhibitors. We add extra stabilizer before filling each export container, record every additive amount in a secure log, and notify importers with certificates. It’s this level of documentation, based on practical trade and mishap history, that keeps return rates low and avoids material loss during customs delays or hot weather storage.
Supporting Future-Ready Applications
HEMA continues to spark innovation in our labs and among our customers. Formulators in medical device startups push for ever-lower residual monomer limits, while energy storage researchers test HEMA-based hydrogels for next-gen batteries. With each new field, the wish lists grow: more UV stability, higher reactivity, zero trace metals, faster polymerization. Having our own R&D team on-site, next to the reactor pits, keeps feedback cycles short. New end-users meet our chemists face-to-face and see why certain process controls stay locked down or why some filter medium is used over cheaper alternatives.
For many new applications, performance under FDA or EU medical guidelines matters as much as technical parameters—every test, from cytotoxicity to extractives, runs in our own labs before material ever enters the customer’s site. This depth of access means real troubleshooting happens fast, which customers rely on for detecting outlier batches or working through regulatory questions. By keeping both R&D and production under one roof, knowledge transfers quickly from plant floor to test lab, helping us keep up with shifting external benchmarks.
Where HEMA Succeeds—And Where It Doesn't
No monomer fits every use, and practical experience brings that lesson home. HEMA’s high water uptake rules it out for applications needing moisture barriers. Coatings teams who try to stretch HEMA ratios into harsh weatherproof films usually run into trouble—film flexibility and adhesion improve, but water intrusion negates barrier effects. Our technical staff fields plenty of calls from users trying out experimental blends. We genuinely share what the practical limits are, since failed scale-ups hurt reputations all around.
On the other hand, where controlled swelling, hydrophilicity, and adhesion matter, few substitutes match HEMA’s performance. Our partners in electronics and 3D printing tell us that the balance of tack, flow, and compatibility with polar solvents makes a noticeable difference at the processing level. Every design-shift or trial batch feeds data straight into process adjustments for future runs—less downtime and fewer rejected lots.
Direct Lessons from Decades of Production
Inside the factory, the culture puts learning above rhetoric. Most improvements in HEMA production come from troubleshooting unexpected outcomes—color shifts from a new methacrylic acid source, a sticky residue on transfer pipes after a summer heat spike, or subtle changes in impurity profiles after a vessel overhaul. Our team has learned to calibrate pH, pressure, and temperature controls not just to spec, but to the real-world performance metrics end users actually care about later.
Each team member contributes to the broader knowledge base, covering real cases: how to spot a pre-polymerizing batch by smell during drum filling; when drum bung torque signals inhibitor loss; what filter media cut water content fastest under high humidity. This combined wisdom feeds into training and operating procedures on site—a world away from lab-only discoveries.
Our partnerships with clients aren’t just supply contracts but information loops. If a polymer processor stumbles on a new application, our operators and chemists rally to reproduce their workflow and pin down differences up close, not from afar. This hands-on approach keeps mistake cycles short and builds trust, even when problems fall outside our own walls.
Summary of Insights
Producing and supplying HEMA over decades means more than reaching a purity standard or ticking a box for industry certifications. At its core, dependable HEMA lets innovators hit their application targets, while keeping daily operations, worker safety, customer satisfaction, and regulatory compliance at the forefront. The difference made by plant-level vigilance, two-way feedback, and willingness to adapt never gets neatly described in a spec sheet but shows its worth in every successful user experience and every avoided mishap. Here, experience and facts set the bar for HEMA’s true value—guaranteeing performance beyond the package label, batch after batch.